Dataset Edition

Présentation générale
Nom du jeu de donnéesAL.Met_Gh - Two meteorological stations, Agoufou, Bamba
Créé le2006-01-20
Projet(s)AMMA > AMMA-LOP
Period
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Contact(s)
Accès aux données Dataset as provided by the Principal Investigator
Site description
RésuméDocumentation of micro-meteorological parameters in the sahelian and saharo-sahelian regions.
Characterization of the spatial variability of the meteorological variables within the Gourma meso scale site.
Data will be used in modelling and assimilation activities, as well as for validation of satellite products.
Strategie d'observationMeasurements are made every mn. The integration time is 15 mn. All the raw data are saved.
Control data are sent through Argos every day.
Site information
Site
Sitemeteorological stations
Type de plateformeIn Situ Land-based Platforms > GROUND STATIONS
Longitude minimale (°)-1.5021Longitude maximale (°)-1.4018
Latitude maximale (°)17.099Latitude minimale (°)14.7284
Altitude min264Altitude max290
Description de l'instrument
Instrument 1
Type d'instrumentIn Situ/Laboratory Instruments > Current/Wind Meters > ANEMOMETERS
FabricantVector
ModèleA100R
Instrument 1, parameter 1
Nom du paramètreWind Speed
Mot-clé du paramètreAtmosphere > Atmospheric Winds > Wind Speed
Unitémeters per second - m/s
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 2
Type d'instrumentIn Situ/Laboratory Instruments > Pressure/Height Meters > BAROMETERS
FabricantSetra
Modèle278
Instrument 2, parameter 1
Nom du paramètreAir Pressure
Mot-clé du paramètreAtmosphere > Atmospheric Pressure
Unitémillibars - mbar
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 3
Type d'instrumentIn Situ/Laboratory Instruments > Temperature/Humidity Sensors > Thermometers > INFRARED THERMOMETERS
FabricantApogee
ModèleIRTS-P
Instrument 3, parameter 1
Nom du paramètreLand Surface Temperature
Mot-clé du paramètreLand Surface > Surface Thermal Properties > Land Surface Temperature
UnitéDegrees Celsius - °C
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 4
Type d'instrumentIn Situ/Laboratory Instruments > Spectrometers/Radiometers > NET RADIOMETERS
FabricantKipp & Zonen
ModèleCNR1
Instrument 4, parameter 1
Nom du paramètreIncoming Longwave Radiation
Mot-clé du paramètreAtmosphere > Atmospheric Radiation
UnitéWatt per square meter - W.m-2
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 4, parameter 2
Nom du paramètreIncoming Shortwave Radiation
Mot-clé du paramètreAtmosphere > Atmospheric Radiation
UnitéWatt per square meter - W.m-2
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 4, parameter 3
Nom du paramètreOutgoing Longwave Radiation
Mot-clé du paramètreAtmosphere > Atmospheric Radiation > Outgoing Longwave Radiation
UnitéWatt per square meter - W.m-2
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 4, parameter 4
Nom du paramètreOutgoing Shortwave Radiation
Mot-clé du paramètreAtmosphere > Atmospheric Radiation
UnitéWatt per square meter - W.m-2
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 5
Type d'instrument
FabricantCampbell
ModèleCS215
Instrument 5, parameter 1
Nom du paramètreAir Temperature
Mot-clé du paramètreAtmosphere > Atmospheric Temperature > Surface Temperature > Air Temperature
UnitéDegrees Celsius - °C
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 5, parameter 2
Nom du paramètreHumidity
Mot-clé du paramètreAtmosphere > Atmospheric Water Vapor > Water Vapor Indicators > Humidity
Unitépercent - %
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 6
Type d'instrument
FabricantDelta T
ModèleBF3
Instrument 6, parameter 1
Nom du paramètreDiffuse Photosynthetically Active Radiation
Mot-clé du paramètreBiosphere > Vegetation
Unitémillimoles per square meter per second
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 6, parameter 2
Nom du paramètreGlobal Photosynthetically Active Radiation
Mot-clé du paramètreBiosphere > Vegetation
Unitémillimoles per square meter per second
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 7
Type d'instrumentIn Situ/Laboratory Instruments > Gauges > RAIN GAUGES
FabricantCampbell
ModèleSBS500
Instrument 7, parameter 1
Nom du paramètrePrecipitation Amount
Mot-clé du paramètreAtmosphere > Precipitation
Unitémillimeters - mm
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 8
Type d'instrumentIn Situ/Laboratory Instruments > Temperature/Humidity Sensors > Thermocouples > THERMOCOUPLES
FabricantRadiospares
ModèleThermocouple Type K
Instrument 8, parameter 1
Nom du paramètreSoil Temperature
Mot-clé du paramètreLand Surface > Soils > Soil Temperature
UnitéDegrees Celsius - °C
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 9
Type d'instrumentIn Situ/Laboratory Instruments > Current/Wind Meters > WIND VANES
FabricantVector
ModèleW200P
Instrument 9, parameter 1
Nom du paramètreWind Direction
Mot-clé du paramètreAtmosphere > Atmospheric Winds > Wind Direction
Unitémeters per second - m/s
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Instrument 10
Type d'instrument
FabricantHukseflux
ModèleHFP01
Instrument 10, parameter 1
Nom du paramètreHeat Flux
Mot-clé du paramètreLand Surface > Soils
UnitéWatt per square meter - W.m-2
Date begin (yyyy-mm-jj)2004-01-01Date end (yyyy-mm-jj)2010-01-01
Précision du capteur / Incertitude
Information sur l'utilisation des données
Conditions d'utilisation des donnéesPermission is granted to use these data in research and publications when accompanied by the following statement: "The AMMA-CATCH regional observing system was set up thanks to an incentive funding of the French Ministry of Research that allowed pooling together various pre-existing small scale observing setups. The continuity and long term perenity of the measurements are made possible by an undisrupted IRD funding since 1990 and by a continuous CNRS-INSU funding since 2005."
Charte d'accès aux données
Base de données
Format des fichiers de données